1. Main Components
- Push button (on/off switch)
- Clip holder
- PX2 housing
- O-ring (seal)
- 2 × Alkaline LR03 / AAA batteries, 1.5 V each
- Lamp head
2. Battery Replacement
- Unscrew the lamp head from the housing.
- Remove empty batteries.
- Insert 2 × 1.5 V AAA alkaline batteries in series, observing correct polarity.
- Screw the lamp head back tightly.
- To prevent accidental switching on, unscrew the head by approx. two turns.
Permitted batteries (certified ATEX / IECEx):
- Varta Longlife Extra 1.5 V AAA LR3
- Varta High Energy 1.5 V AAA LR3
- Energizer Ultra 1.5 V AAA LR3
- Duracell Plus Power 1.5 V AAA LR3
- Energizer Industrial 1.5 V AAA LR3
- Varta Industrial Pro 1.5 V AAA LR3
- Daimon 1.5 V AAA LR3
3. Battery Warnings
- Do not use damaged, leaking or corroded batteries.
- Never mix different types, brands, or ages of batteries.
- Risk of leakage of corrosive liquids or gases.
- Remove the batteries if the lamp will not be used for a long time.
Technical Note: Why batteries from different manufacturers must not be mixed
Even if all batteries are labeled “AAA 1.5 V,” they are not identical:
- Chemical composition: each brand uses different electrolytes and materials, which change electrical behavior.
- Internal resistance and capacity: small variations mean one cell may discharge faster.
- Voltage balance: weaker cells may be forced into reverse polarity by stronger ones, causing leaks or rupture.
- Heat generation: mismatched batteries can overheat, which is especially dangerous in ATEX environments.
- Certification validity: ATEX/IECEx safety approval applies only to specified battery types. Mixing breaks compliance.
⚠️ Mixing batteries from different brands or ages leads to uneven discharge, overheating, leakage, polarity reversal, and loss of safety certification.
4. Cleaning
- Danger of electrostatic charging of the plastic parts of the lamp.
- Clean the glass and housing only with cold or lukewarm (≈25–40 °C) water.
- If necessary, add a mild detergent (gentle, non-abrasive soap).
- Use a soft, lint-free cloth (that does not shed fibers) or a viscose sponge.
5. O-Ring
- Check the O-ring before every use.
- O-ring must always be clean.
- Replace the O-ring if damaged.
- Do not use any tools for replacement.
6. Safety Notes
- Do not open the lamp in explosive atmospheres.
- Maximum ambient temperature range: –20 °C to +40 °C.
- Protect the lamp from long-term direct sunlight.
- Only use original spare parts supplied by the manufacturer.
- The product complies with Directive ATEX 2014/34/EU.
Optical safety warning (EN 62471):
- Risk Group RG-1.
- Do not stare at the LED source for a long period. May be harmful to eyes.
7. Disposal and Recycling
Batteries, rechargeable batteries and electrical devices must not be disposed of with household waste.
They may contain hazardous substances such as:
- Cd (Cadmium)
- Hg (Mercury)
- Pb (Lead)
Therefore, they must be taken to designated collection points or returned to authorized dealers.
Compliance with this regulation is mandatory and contributes significantly to environmental protection.
8. Technical Data PX2
- Dimensions: 142 mm length × 22 mm diameter
- Weight: approx. 45 g (without batteries)
- Light source: white LED
- Material: Polycarbonate (PC)
- Power supply: 2 × AAA alkaline batteries (LR03, 1.5 V)
- Luminous flux: approx. 30 lm
- Beam distance: 35 m × 0.3–5 m
- Operating time: approx. 8 h
9. EU Declarations of Conformity (DoC)
Manufacturer: PARAT Solutions GmbH, 94065 Waldkirchen, Germany
We hereby declare under our sole responsibility that the following products comply with the essential requirements of the relevant EU directives:
PARALUX PX1 Shorty
- Marking: II 1G Ex ia op is IIC T4 Ga / II 2D Ex ia op is IIIC T105°C Db IP 68
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
PARALUX PX2
- Marking: II 2G Ex ib op is IIB T4 Gb / II 2D Ex ib op is IIIC T105°C Db IP 68
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
PARALUX PX2 PC LED 125
- Marking: II 2G Ex ib IIB T4 Gb
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
PARALUX PX3 PC LED
- Marking: II 3G Ex nA IIC T4 Gc
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
PARALUX PX0 XAG LED 123 / PX1 / PX0 PC LED 123
- Marking: II 1G Ex ia op is IIC T4 Ga / II 2D Ex ib IIIC T105°C Db IP 68
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
PARALUX HL-P1 (safety headlamp)
- Marking: II 2G Ex ib IIB T4 Gb
- Directives: ATEX 2014/34/EU, RoHS 2011/65/EU
10. Applied Harmonized Standards
- EN IEC 60079-0:2018
- IEC 60079-0:2017
- EN 60079-11:2012
- IEC 60079-11:2011 + Cor.:2012
- EN 60079-28:2015
- IEC 60079-28:2015
- EN 62471:2008
- IEC 62471:2006
- EN IEC 63000:2018
- DIN EN 60529:2014
11. Certification and Notified Body
EC type examination certificates:
- BVS 12 ATEX E 059 X
- BVS 13 ATEX E 021 X
- BVS 13 ATEX E 051 X
- BVS 19 ATEX E 054 X
Product quality assessment carried out by:
DEKRA Testing and Certification GmbH, 44809 Bochum, Germany
Notified Body No. 0158
12. Signature
Neureichenau, 11.05.2021
Dominik Mösl
Head of Engineering / Product Manager Cases & Lights
PARAT Solutions GmbH
(Signature on the original DoC documents)
© PARAT Solutions GmbH.
We reserve the right to technical modifications and printing errors.
Glossary of Acronyms and Abbreviations (Alphabetical)
- AAA / LR03 → Standard 1.5 V cylindrical battery (small size).
- ATEX (ATmosphères EXplosibles) → EU directive for equipment used in explosive atmospheres (2014/34/EU).
- BVS → German test body (Bergbau-Versuchsstrecke), issuer of ATEX certificates.
- Cd (Cadmium) → Toxic heavy metal.
- Db / Dc → Dust equipment protection levels (high / enhanced).
- DEKRA → International certification body; Notified Body No. 0158 (Germany).
- DIN (Deutsches Institut für Normung) → German national standards institute.
- DoC (Declaration of Conformity) → EU document declaring product compliance with directives.
- EN (European Norm) → Harmonized European standards.
- Ex → Explosion-protection marking under ATEX/IECEx.
- Ga / Gb / Gc → Gas equipment protection levels (very high / high / enhanced).
- Hg (Mercury) → Toxic liquid metal.
- IEC (International Electrotechnical Commission) → International standards organization.
- IP (Ingress Protection) → Rating for dust/water resistance (e.g., IP 68 = dust-tight and suitable for continuous immersion).
- LED (Light Emitting Diode) → Semiconductor light source.
- lm (lumen) → Unit of luminous flux (total light output).
- Pb (Lead) → Toxic heavy metal.
- RG-1 (Risk Group 1) → Low photobiological risk classification (EN 62471).
- RoHS (Restriction of Hazardous Substances Directive) → EU directive limiting hazardous substances in EEE (2011/65/EU).
- T4 → Temperature class (max. 135 °C surface temperature).
- V (Volt) → Unit of electric potential.